Malvern zetasizer add refractive index
Malvern zetasizer add refractive index









malvern zetasizer add refractive index

Organic solvents such as alcohols generally promote de-agglomeration of particles, whereas acetone or aromatics tend to promote particle adhesion on the cell wall, thus making measurements badly reproducible.ĭispersants have to be selected for each particle and solvent, but polyphosphates are usually applied for insoluble materials, with hexametaphosphate being most effective in most cases, although solutions cannot be stored for more than one day, since the dispersant loses its activity. For materials which are insoluble but hardly wettable by water, adding an inorganic alcohol or a neutral detergent is effective, although detergents might cause foam formation. Usually deionised water is used for insoluble materials, although the pH of the deionised water could affect the zeta-potential of the particles.

  • Having a different density from that of the sample in case of sedimentation.
  • Not dissolving the particles, or acting upon them by shrinking or swelling.
  • Having a good affinity for the particles.
  • The solvent should satisfy the following conditions: The effect of these parameters on the particle sizing results will be illustrated in Section 3 of the paper. The main parameters that are to be considered in particle size measurement are listed in Table 2. In most common suspension analysers, particles are dispersed in a solvent, mostly using a dispersant to lower the surface tension. The accuracy of the particle size analysis is largely dependent on a number of parameters, including the sample preparation, the degree of dispersion and the analysis itself.

    malvern zetasizer add refractive index

    The authors therefore conducted a number of experiments on a Malvern laser analyser to establish conditions and associated operating conditions required to improve the accuracy of the measurement. The laser diffraction and scattering method is one of the most popular particle size analysers. Differences in presenting the particle size distributions.

    malvern zetasizer add refractive index

    These differences are due to several reasons, associated with: Unfortunately, no information is given about comparing results produced by different methods, and such a comparison often creates the impression that results are very different. 16-21 Each standard describes at some degree the advantages and limitations of particular methods. Procedures should hence be standardized and this has been presented in the ISO standards for each of the measurement techniques.

    malvern zetasizer add refractive index

    It is essential to respect a number of rules, related to the sample preparation, the measurement procedure and to the analysers themselves. And yet, repeat determinations often lack consistency and accuracy. The final objective of the particle size analysis technology is to accurately measure the particle size distribution in any size range. Table 1 Common particle size analysers and some of the suppliers.